Stops rising damp and dries out walls
Guard Hardener® RD is a product for treating humidity in walls, rising damp, efflorescence and surface salts. 
It dries and consolidates friable substrates damaged by intrusion of water and damp. It therefore mitigates problems of rising damp.
Guard Hardener® RD is applied by injection into walls. 
Very dense, Guard Hardener® RD uses water as a vehicle and makes use of it to harden and mineralise to create a waterproof barrier that will prevent any rising damp.
  • Solves damp problems.
  • Creates a barrier to stop problems rising damp.
  • Consolidates materials.
  • Colourless.
  • Water-based product, solvent-free. 
Apply by gravity or with an injections machine.
Clean tools and equipment immediately after use with water.
  • Treatment is by injection in the base of the wall to be treated, 10 cm higher than the ground.
  • Drill 2 staggered rows of holes (Ø15 - 30 mm) not more than 30 cm apart at an angle of 30° to 40° downwards to a depth of 2/3 of the thickness of the wall.
  • For a very thick wall (> 60 cm) the treatment must be applied from both sides.
  • Inject the product into each hole until it comes back out of the hole, then seal with cement containing 3% to 5% Guard Hardener® RD.
  • Make sure that no hole communicates with a cavity, causing running water. In the case of a cavity, plug it with a mixture of cement and product and re-drill after 24 hours.
  • Full effects achieved after drying for several weeks, depending on the composition of the wall.
  • Appearence: Uncoloured.
  • Physical state at 20°C: Liquid.
  • Odour: None.
  • pH: 12 ± 0.5.
  • Boiling point [°C]: 100°C.
  • Density: 1.25 ± 0.01.
  • Solubility in water [vol/vol]: Total.
  • Flash point [°C]: Not applicable.
  • VOCs: < 1 g/l*.
The following values are for guidance only:
  • Treatment by injection against rising damp: ± 2 to 3 litres/meter (for a wall of 20 cm thickness).
5 litres.
  • Keep in a dry place (between 5°C and 30°C).
  • Storage: 24 months following the production date when kept in the original unopened container.
  • For ideal application and effective results, Guard Hardener® RD must be used when the substrate temperature is between 5°C and 30°C.
  • Do not apply in rain or very hot weather. Air temperature between 5°C and 30°C.
  • Do not apply to plaster or fragile materials, organic, metallic or impermeable materials.
  • Product is alkaline. Handle preferably with gloves and goggles. Protect painted surfaces, glass, tiles and light alloys (aluminium, chrome, copper, zinc, etc). Accidental splashes should be rinsed off immediately with water.
  • Do not dilute or mix with another product.
  • Respiratory protection: Under normal conditions of use where adequate ventilation is available, no special respiratory protection equipment is needed.
  • Hand protection: Wear rubber gloves resistant to chemical products.
  • Skin protection: No special protective clothing or skin protection is required under normal conditions of use.
  • Eye protection: If there is a real risk of splashing, wear protective goggles.
  • If swallowed: Do not induce vomiting. Contact a doctor or a specialist.
KEEP OUT OF THE REACH OF CHILDREN
Physical Propeties/Chemical:
  • Mixture of sodium silicate in an aqueous phase.
Tips and tricks:
  • Guard Hardener® RD can be applied by spray in case of damp friable surfaces (indoor walls, basements...).
  • In this case, apply the product neat in one or two layers (drying time between each layer: 1 hour).
GUARD INDUSTRIE (FRANCE)
Daniel Bruyat: Business Director
Phone: (+33) 65 84 46 13 73
Website: www.guardindustrie.com     
 
NANO PHAM GROUP (VIET NAM)
Hotline: (+84) 918 244 844
Website:
 
Important: The content of this documentation is based on our experience with the product. Guard Industry guarantees the quality of its products but expresslydisclaims all liability if the user does not follow the recommendations and conditions of use of the products, especially but not exclusively in the case of faultyapplication, application by untrained personnel, use of products not compatible
with Guard Industry products, or adverse weather conditions For more information, consult the safety data sheet.
Accessing: 98
  • Ho Chi Minh
  • 97 Street No. 7, An Phu- An Khanh Urban Area, An Phu Ward (District 2), Thu Duc City, Ho Chi Minh City
  • Quang Ngai
  • 370 Nguyen Tu Tan Street, Tran Phu Ward, Quang Ngai City, Quang Ngai Province
  • Danang
  • K21/H2/1 Nguyen Van Hue Street, Thanh Khe Tay Ward, Thanh Khe District, Da Nang City
  • Thua Thien Hue
  • B08 The Manor Crown, To Huu Street, Hue City, Thua Thien Hue Province
  • Quang Binh
  • 37 Tran Kinh Street, Dong Hoi City, Quang Binh Province
  • Ha Tinh
  • 64 Le Thai To Street, Ky Thinh Commune, Ky Anh District, Ha Tinh Province
  • Thai Binh
  • 36A Quang Trung Street, Tran Hung Ward, Thai Binh Province
  • Thanh Hoa
  • 597 Street 1, Quang Hung Ward, Thanh Hoa City, Thanh Hoa Province
  • Hanoi
  • 99 Nhat Chieu Street, Nhat Tan Ward, Tay Ho District, Hanoi City
Total online: 1.665.344