Clear primer for adhesion of two-component products to concrete
PrimerGuard®Special UHPCis a product designed to be used as a primer before applying two-component products from the Guard Industrie range – ProtectGuard®ColorTwo-component or AntiGraffitiGuard®Special Concrete on UHPC. Application of PrimerGuard®Special UHPC is essential to ensure the perfect final appearance and performance of the coating,PrimerGuard®Special UHPC promotes adhesion by its ability to bond strongly to UHPC. PrimerGuard®Special UHPC is a penetrating product, the substrate remains permeable to air and water vapour.
PrimerGuard®Special UHPC is used indoors and outdoors on vertical UHPC (> 28 days). It is intended to be applied before two-component products such as ProtectGuard®ColorTwo-component or AntiGraffitiGuard®Special Concrete.
  • Penetrating product.
  • Allows the treated material to breathe.
  • Essential for adhesion of two-component products.
  • Ready to use.
  • Easy to use.
  • Non flammable.
Apply using an airless or HVLP gun or a roller. 
Clean tools and equipment immediately after use with water.
  • Sand the roughness of the support if necessary then dust the support.
  • Apply the product to a surface that is clean, dust-free, grease-free and dry. To remove stains and marks of pollution use Guard Cleaner®Polluted Facades orGuard Cleaner®EcoSoiled Floors. For efflorescence, laitance or concrete bloom use Guard Remover®EcoEfflorescence & Cement.
  • Rinse thoroughly with water.
  • Use neat, do not dilute.
  • Shake the product well for 1 minute before use.
  • Always carry out a preliminary test.
  • Apply one coat from the bottom up.
  • It is essential that PrimerGuard®Special UHPC feel tacky to the finger. If it does not, apply another coat.
  • PrimerGuard®Special UHPC must be protected from dust for the first 3 hours following application.
  • PrimerGuard®Special UHPC is ready to receive a coat of another product after 4 hours at a temperature of 20°C.
  • However, we recommend applying the two-component product sold with it within a time window of 4 hours to 48 hours after application of PrimerGuard®Special UHPC.
  • Physical state at 20°C: Liquid.
  • Appearence: Whitish.
  • Odour: OdourlesspH: 5 ± 1.
  • Boiling point [°C]: 100°C.
  • Density: 1.01 ± 0.02.
  • Solubility in water [vol/vol]: Total.
  • Flash point [°C]: Not applicable.
Coverage depends on the porosity of the material. The figures below should be used only as a general guideline: 8 to 15 m2/litre.
 1, 5 and 25 litres.
  • Keep in a dry place (between 5°C and 30°C).
  • Storage: 12 months following the production date when kept in the original unopened container.
Environment-friendly product:
  • Water-based product.
  • Petroleum solvent and silicone free.
  • Safe and non toxic.
  • VOC < 1 g/l*.
  • It is essential to shake the can for 1 minute before use.
  • Do not treat surfaces until they have first been cleaned of all atmospheric pollution and all stains.
  • For ideal application and effective protection, it is essential that PrimerGuard®Special UHPC be used when the substrate temperature is between 10°C and 30°C.
  • Do not apply in rain or very hot weather. Air temperature between 5°C and 30°C.
  • Air humidity rate < 80%.
  • Material humidity rate < 5%.
  • Do not dilute or mix with another product.
  • Respiratory protection: We recommend to wear a P3 respiratory protection.
  • Hand protection: Wear protective gloves (EN 374-1:2003).
  • Skin protection: Wear protective clothing.
  • Eye protection: If there is a real risk of splashing, wear protective goggles.
  • If swallowed: Do not induce vomiting. Contact a doctor or a specialist.
PRODUCT FOR PROFESSIONAL USE
Chemical nature:
Aqueous-phase acrylic copolymer.
GUARD INDUSTRIE (FRANCE)
Daniel Bruyat: Business Director
Phone: (+33) 65 84 46 13 73
Website: www.guardindustrie.com     
 
NANO PHAM GROUP (VIET NAM)
Hotline: +84 918 244 844
Website:
 
Important: The content of this documentation is based on our experience with the product. Guard Industry guarantees the quality of its products but expresslydisclaims all liability if the user does not follow the recommendations and conditions of use of the products, especially but not exclusively in the case of faultyapplication, application by untrained personnel, use of products not compatible
with Guard Industry products, or adverse weather conditions For more information, consult the safety data sheet.
Accessing: 97
  • Ho Chi Minh
  • 97 Street No. 7, An Phu- An Khanh Urban Area, An Phu Ward (District 2), Thu Duc City, Ho Chi Minh City
  • Quang Ngai
  • 370 Nguyen Tu Tan Street, Tran Phu Ward, Quang Ngai City, Quang Ngai Province
  • Danang
  • K21/H2/1 Nguyen Van Hue Street, Thanh Khe Tay Ward, Thanh Khe District, Da Nang City
  • Thua Thien Hue
  • B08 The Manor Crown, To Huu Street, Hue City, Thua Thien Hue Province
  • Quang Binh
  • 37 Tran Kinh Street, Dong Hoi City, Quang Binh Province
  • Ha Tinh
  • 64 Le Thai To Street, Ky Thinh Commune, Ky Anh District, Ha Tinh Province
  • Thai Binh
  • 36A Quang Trung Street, Tran Hung Ward, Thai Binh Province
  • Thanh Hoa
  • 597 Street 1, Quang Hung Ward, Thanh Hoa City, Thanh Hoa Province
  • Hanoi
  • 99 Nhat Chieu Street, Nhat Tan Ward, Tay Ho District, Hanoi City
Total online: 1.665.425